Produktdetails:
|
| Frequenz: | von 1 bis 1280 Hz ≤±0,01 % | Sonde: | 5-mm-, 8-mm- und 11-mm-Sonden |
|---|---|---|---|
| Reichweite: | 0~4,0 mm | Anzeige: | Anzeige mit 3 1/2 Ziffern für Vibration und Frequenz |
| Hervorheben: | HUATEC HG-5026 vibration calibrator,battery powered vibration calibrator,vibration calibrator for non-destructive testing |
||
HG-5026 Battery Powered Vibration Calibrator
HG-5026 battery powered vibration calibrator can be used to calibrate vibration accelerometer, velocity and proximity transducer and also a vibration measuring instrument. Standard sine signal vibration at any frequency from 1 to 1280 Hz can be defined in the calibrator. The amplitude of the acceleration, velocity and displacement, can be defined through potentiometers and shown on digital displays. Either horizontal or vertical vibration can be generated. HG-5026 combines sine signal generator, power amplifier, standard transducer, vibration meter and a shaker in one and features a small volume, high accuracy and easy operation. It can be used either in laboratory or on site.
Maximum vibration amplitude & transducer weight
| Wt Freq |
<100g | <250g | <500g | ||||||
|---|---|---|---|---|---|---|---|---|---|
| a(m/S2) | v(mm/S) | d(μm) | a(m/S2) | v(mm/S) | d(μm) | a(m/S2) | v(mm/S) | d(μm) | |
| 10Hz | 2.5 | 28 | 1300 | 3.5 | 40 | 1800 | 4 | 45 | 2000 |
| 20Hz | 15 | 85 | 1900 | 10 | 60 | 1300 | 5 | 28 | 640 |
| 40Hz | 60 | 170 | 2000 | 35 | 100 | 1100 | 12 | 35 | 380 |
| 80Hz | 100 | 141 | 800 | 40 | 60 | 320 | 14 | 20 | 110 |
| 160Hz | 75 | 53 | 150 | 35 | 25 | 70 | 12 | 8.5 | 24 |
| 320Hz | 50 | 18 | 25 | 30 | 10 | 15 | 10 | 3.5 | 5 |
| 640Hz | 30 | 5 | 3 | 20 | 3.5 | 2 | 6 | 1 | * |
| 1280Hz | 23 | 2 | * | 10 | 0.9 | * | 5 | 0.4 | * |
Note: When the frequency is high, due to the very small value of the vibration displacement, the calibrator does not display the amplitude of the vibration signal at these points.
Battery introduction:
Specifications
Frequency: from 1 to 1280 Hz ≤±0.01%
Amplitude accuracy:
Amplitude accuracy:
Acceleration (@10m/s2 pk) 40Hz to 320Hz + 0.3dB + 1digit
20Hz to 640Hz + 0.5dB +1digit
Velocity (@20mm/sec rms) 40Hz to 320Hz +0.5dB +1digit
Displacement (@50μm pk-pk) 40Hz to 320Hz + 0.5dB + 1digit
Proximity probe linearity calibration kits
Probe: 5mm,8mm and 11mm probes Range: 0~4.0mm
Weight of velocity probe: <650g
Display: 3 1/2 digit display for vibration and frequency
Size: 300 x250 x210(mm) Net Weight: 6 kg
Temperature: Operation: 0oC to 50 oC Storage: -20 oC to 70 oC
Power: 220Vac (optional 110Vac)