Produktdetails:
|
| Produktname: | Digitaler Plattendetektor | Pixelgröße: | 140 um |
|---|---|---|---|
| Pixelmatrix: | 3072×3072 | Energiebereich: | 40-350 kV |
| Hervorheben: | industrial DR X-ray detector,high-definition digital plate detector,non-destructive testing X-ray equipment |
||
DR System High Performance Industrial DR X-ray High-Definition Digital Plate Detector
Features:
HUATEC HDR-4343 flat detector, is a fixed low noise static flat detector, the front panel of the detector using amorphous silicon (a-Si) material technology, the flat detector using amorphous silicon material technology, with high image quality, large dynamic range, a wide range of terminal applications. The product is designed to be fixed and has a multi-gain programmed adjustment gear, which makes it suitable for high sensitivity applications as well as large dynamic range scenarios. Based on the above characteristics, the HUATEC HDR-4343 detector can be widely suitable for medical, industrial, pet and other applications.
Amorphous silicon material itself has many advantages, compared with other material technologies, the more prominent advantages are:
Large dynamic dose range
Long radiation lifetime
Parameters:
| HUATEC HDR-4343 | |
| Pixel size | 140 um |
| Pixel matrix | 3072×3072 |
| Effective area | 434×434mm |
| The depth of the quantitative | 16-bit |
| Gain the gears | Multi-gain gear |
| scintillation | GOS/CSI is optional |
| Dustproof and waterproof | IPXO |
| External interface | Wired: 1Gbps Ethernet |
| High tension line | |
| power supply | |
| Image correction | Software calibration, hardware calibration |
| Radiation resistance | ≥10000Gy |
| Dynamic range | ≥85dB |
| Spatial resolution | 3.5lp/mm |
| Image acquisition time | ≤1s |
| Energy range | 40-350kV |
| Overall dimensions | 470×470×30mm |
| Weight | 9kg |
HUATEC digital image processing and enhancement software
![]()
HUATEC image enhancement and storage system integration the most practical processing and filtering features are designed for real-time X-ray imaging systems, increasing the sensitivity of processed images by an average of 0.6% to 0.8%. With the help of high-speed Ethernet port, you can get both static and dynamic images at the same time, and save them as 8/16bit image format, and directly burn them to DVD for permanent storage, which is convenient for archiving and reviewing the detection data, and saves detection cost and archive space at the same time.
Flat plate connection and control
Gigabit net plate connection, and prompt connection state and fault
The offset/gain/bad pixel correction
The offset/gain/bad pixel correction, can choose whether overlay
According to proportion
The current frame rate
Software process
Pixel gray value display
Real-time image display and processing
Real-time image ROI fast grayscale mapping, easy to quickly observe the effective image of the region of interest
Real-time display integral noise reduction: 2/4/8 frames optional
Real-time display algorithm processing: negative/color/binarization
Real-time display of image sharpening and enhancement
Image integral acquisition: 8/16/32/64/128/256 frame stack
Continuous Video Recording: Compression format is optional
Image/video naming and name automatic sequential compilation
0-65536, 16bit gray scale adjustment
GAM/Contrast/Brightness/Threshold adjustment
Picture information mark, a number of contents can be filled
Still image processing
ROI fast gray scale mapping, easy to quickly observe the effective image of the region of interest
BMP/PNG/JPG/TIFF (8bit/16bit)/RAW/HIS/DCM file read
Grayscale/negative/pseudo-color/binarization/sharpening/enhancement algorithm processing
Magnifying glass, 1-5 times magnification observation
Image to flip
Gamma/ contrast/brightness/threshold adjustment
Dimension calibration and measurement, and can mark the required information on the picture
Ouble filament image quality meter automatic verification
It meets the standard requirements of NB/T 47013.11-2015 "Non-destructive Testing of Pressure Equipment X-ray Digital Imaging Testing". It can automatically verify the double-filament image quality meter and measure SNR.
Portable high frequency X-ray flaw detector
![]()
Main performance:
35℃ 300kV /3mA, 250kV /3mA conditions can be continuously exposed;
Wide input voltage range, to meet the power supply of various generators;
Light weight, strong penetration, stable performance;
More suitable for use in harsh environment, humid environment;
The operation interface is intuitive and the operation is simple.
Main technical parameters
| Project name | XXG-300GF | XXG-250GF | |
| X ray generator | weight | 27kg | 25kg |
| Size | Φ295×752 (Φ×L) | Φ295×704 (Φ×L) | |
| Controller | weight | 11kg | 11kg |
| Size | 410×228×300 (L×B×H) | 410×228×300 (L×B×H) | |
| Focus size | 3.0×3.0 | 3.0×3.0 | |
| Radiation Angle | 40°×40° | 40°×40° | |
| Maximum penetration(Fe) | 70mm (A3) | 60mm (A3) | |
| kV Adjusting range | 120~300 kV | 70~250 kV | |
| mA Adjusting range | 0.5~3 mA(step 0.1mA) | 0.5~3 mA(step 0.1mA) | |
| Maximum power | 900W | 900W | |
| Leakage radiation value | Max.5.0msv/h | Max.5.0msv/h | |
| Working temperature | -20˚C~+50˚C | -20˚C~+50˚C | |
| Storage temperature | -25˚C~+70˚C | -25˚C~+70˚C | |
| Supply voltage | 85~264 VAC | 85~264 VAC | |
| Power frequency | 45~65 Hz | 45~65 Hz | |
![]()
Ansprechpartner: Ms. Shifen Yuan
Telefon: 8610 82921131,8618610328618
Faxen: 86-10-82916893